::* Align the rear ends of the TIP2k and O2k, if you use [[Microsyringe\500 mm3\TIP2k |500 ยตl syringes]].
::* Align the rear ends of the TIP2k and O2k, if you use [[Microsyringe\500 mm3\TIP2k |500 ยตl syringes]].


== Technical characteristics ==
''Titration:''
Programmable, automatic titration regimes, with titration volumes of 0.05 to 250 ยตl, variable titration intervals and duration of titration pulses.


''Injection:''
Steady-state injection: Operation at quasi steady-states by continuous injection of substrates at limiting rates of consumption, providing new flexibility in experimental design by combining the technical advantages of closed and open systems. Programmable injection flows: 0.01 to 25 ยตl.s-1.
Ramp injection (MiPNet04.05, see above): Ramp increase of effector concentrations by "continuous titration".
*DatLab software for feedback control by the the TIP2k: for steady-state respirometry at selected oxygen levels and pH-stat applications.


== TIP2k-Syringes ==
== TIP2k-Syringes ==

Revision as of 12:42, 5 September 2019

                



TIP2k-Module

O2k-Catalogue

Description TIP2k-Module - Titration-Injection microPump (TIP2k) for two-channel operation with the O2k-FluoRespirometer with automatic control by DatLab of programmable titration regimes and feedback control (oxystat, pH-stat). The TIP2k-Module includes TIP2k-Accessories: 4 Microinjection syringes, 1 Pkg. TIP2k-Needle Spacers with mounting tool, 1 TIP2k-Needle Safety Support and 1 Pkg. TIP2k Filter Papers, and the newest DatLab version.
Product ID 11100-03
Type O2k, O2k-Module, Microsyringe, O2k-FluoRespirometer
Link MiPNet12.10 TIP2k-manual, MiPNet04.05 Titration-Injection
Image
TIP2k with 200 mm3 microsyringe.JPG


MitoPedia O2k and high-resolution respirometry: O2k hardware 

TIP2k-Module consists of:

O2k with TIP2k

ยป TIP2k-Manual
The TIP2k is fully supported by the O2k.

The TIP2k is placed at the top of the Oroboros O2k. It does not need any extra bench space.

Technical characteristics

Titration: Programmable, automatic titration regimes, with titration volumes of 0.05 to 250 ยตl, variable titration intervals and duration of titration pulses.

Injection: Steady-state injection: Operation at quasi steady-states by continuous injection of substrates at limiting rates of consumption, providing new flexibility in experimental design by combining the technical advantages of closed and open systems. Programmable injection flows: 0.01 to 25 ยตl.s-1. Ramp injection (MiPNet04.05, see above): Ramp increase of effector concentrations by "continuous titration".

  • DatLab software for feedback control by the the TIP2k: for steady-state respirometry at selected oxygen levels and pH-stat applications.

TIP2k-Syringes

ยป SOP: Handling microsyringes
  • Rinse the outside with water immediately after use.
  • Wash 3 x with last used solvent, rinse with EtOH.
  • Storage: ethanol (short), dry (longtime).
  • Rinse with pure solvent before use.


List of O2k-Publications: TIP2k

Cookies help us deliver our services. By using our services, you agree to our use of cookies.