O2k-Chamber Holder: Difference between revisions
From Bioblast
No edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
{{Product | {{Product | ||
|description='''O2k-Chamber Holder''' (blue POM) for PVDF or PEEK stoppers (2-mL [[O2k- | |description='''O2k-Chamber Holder''' (blue POM) for PVDF or PEEK stoppers (2-mL [[O2k-chamber]]), with [[O-ring\Viton\18x2 mm]] and [[V-ring\30-35-4.5 mm]]. Two units of this item are standard components mounted on the [[O2k-Main Unit]]. | ||
|product id=22100-01 | |product id=22100-01 | ||
|product type=O2k-FluoRespirometer, Startup O2k-Respirometer, Power O2k-FluoRespirometer, Power O2k-Respirometer | |product type=O2k-FluoRespirometer, Startup O2k-Respirometer, Power O2k-FluoRespirometer, Power O2k-Respirometer | ||
Line 7: | Line 7: | ||
}} | }} | ||
== Cleaning == | == Cleaning == | ||
:::: After the [[O2k-Chamber]] is inserted into the copper block, the O2k-Chamber Holder is screwed on top of the chamber into the copper block to hold the chamber into a tight vertical position (O-ring) and prevent liquid to flow from the stainless steel housing into the space outside of the chamber (V-ring). | :::: After the [[O2k-chamber |O2k-Chamber]] is inserted into the copper block, the O2k-Chamber Holder is screwed on top of the chamber into the copper block to hold the chamber into a tight vertical position (O-ring) and prevent liquid to flow from the stainless steel housing into the space outside of the chamber (V-ring). | ||
[[Image:PlayVideo.jpg|50px|link=https://www.youtube.com/watch?v=1JffCpapX6A]] [https://www.youtube.com/watch?v=1JffCpapX6A A1 Insert O2k-Chamber] | [[Image:PlayVideo.jpg|50px|link=https://www.youtube.com/watch?v=1JffCpapX6A]] [https://www.youtube.com/watch?v=1JffCpapX6A A1 Insert O2k-Chamber] |
Revision as of 11:57, 18 October 2020
O2k-Chamber Holder
Description | O2k-Chamber Holder (blue POM) for PVDF or PEEK stoppers (2-mL O2k-chamber), with O-ring\Viton\18x2 mm and V-ring\30-35-4.5 mm. Two units of this item are standard components mounted on the O2k-Main Unit. |
---|---|
Product ID | 22100-01 |
Type | O2k-FluoRespirometer, Startup O2k-Respirometer, Power O2k-FluoRespirometer, Power O2k-Respirometer |
Link | O2k-FluoRespirometer |
Image |
Cleaning
- After the O2k-Chamber is inserted into the copper block, the O2k-Chamber Holder is screwed on top of the chamber into the copper block to hold the chamber into a tight vertical position (O-ring) and prevent liquid to flow from the stainless steel housing into the space outside of the chamber (V-ring).