MiPNet22.11 O2k-FluoRespirometer manual: Difference between revisions
From Bioblast
No edit summary |
No edit summary |
||
Line 4: | Line 4: | ||
|info=[[File:PDF.jpg|100px|link=http://wiki.oroboros.at/images/2/29/MiPNet22.11_O2k-FluoRespirometer-manual.pdf |Bioblast pdf]]Β» [http://wiki.oroboros.at/index.php/File:MiPNet22.11_O2k-FluoRespirometer-manual.pdf Versions] | |info=[[File:PDF.jpg|100px|link=http://wiki.oroboros.at/images/2/29/MiPNet22.11_O2k-FluoRespirometer-manual.pdf |Bioblast pdf]]Β» [http://wiki.oroboros.at/index.php/File:MiPNet22.11_O2k-FluoRespirometer-manual.pdf Versions] | ||
|authors=Oroboros | |authors=Oroboros | ||
|year= | |year=2020-10-16 | ||
|journal=Mitochondr Physiol Network | |journal=Mitochondr Physiol Network | ||
|abstract=Gnaiger E, MΓ©szΓ‘ros A, Gradl L, Gradl P (2019) O2k-FluoRespirometer manual. Mitochondr Physiol Network 22.11(07):1-17. Β | |abstract=Gnaiger E, MΓ©szΓ‘ros A, Gradl L, Gradl P (2019) O2k-FluoRespirometer manual. Mitochondr Physiol Network 22.11(07):1-17. Β | ||
Line 11: | Line 11: | ||
|mipnetlab=AT_Innsbruck_Oroboros | |mipnetlab=AT_Innsbruck_Oroboros | ||
}} | }} | ||
== Important updates == | |||
:::* Version 08 (2020-10-16) Section '''5.4. O2k-Chamber volume calibration''' | |||
::::# Instructions are added for the 0.5-mL O2k-chamber volume calibration ([[O2k-sV-Module]]). | |||
::::# Volume calibration of 2-mL O2k-chamber: Fill open chamber with 2.07 mL water (not 2.1 mL). The volume of the stopper capillary is 0.07 mL (not 0.085 mL). | |||
{{Labeling | {{Labeling | ||
|area=Instruments;methods | |area=Instruments;methods |
Revision as of 15:35, 16 October 2020
MiPNet22.11 O2k-FluoRespirometer manual |
O2k-FluoRespirometer manual. |
Β» Β» Versions
Oroboros (2020-10-16) Mitochondr Physiol Network
Abstract: Gnaiger E, MΓ©szΓ‘ros A, Gradl L, Gradl P (2019) O2k-FluoRespirometer manual. Mitochondr Physiol Network 22.11(07):1-17.
- Β» Current O2k-series: NextGen-O2k Series XB and O2k Series J
- Β» Current software versions DatLab 8.0: MitoPedia: DatLab
- Further details: Β» MitoPedia: O2k-Open Support
- Β» Product: DatLab 7, O2k-FluoRespirometer, O2k-Catalogue
β’ O2k-Network Lab: AT_Innsbruck_Oroboros
Important updates
- Version 08 (2020-10-16) Section 5.4. O2k-Chamber volume calibration
- Instructions are added for the 0.5-mL O2k-chamber volume calibration (O2k-sV-Module).
- Volume calibration of 2-mL O2k-chamber: Fill open chamber with 2.07 mL water (not 2.1 mL). The volume of the stopper capillary is 0.07 mL (not 0.085 mL).
Labels: MiParea: Instruments;methods