You do not have permission to edit this page, for the following reasons:
Free text:
{{Technical support}} __TOC__ {{MitoPedia without banner |abbr= |description=[[Image:O2k-Core-Concept.jpg|200px|right]] '''Oroboros O2k-Core - Former Series''' '''(O2k-Series D - G)''' - the experimental system complete for basic [[high-resolution respirometry]] (HRR). The O2k-Core includes the [[O2k-Main Unit]] with stainless steel housing, [[O2k-Assembly Kit]], two [[OroboPOS]] (polarographic oxygen sensors) and [[OroboPOS-Service Kit]], [[DatLab]] software, the [[ISS-Integrated Suction System]] and the [[O2k-Titration Set]]. The O2k-Core supports all add-on O2k-Modules of the O2k. On-line display of oxygen flux (rate of respiration) is provided in addition to the conventional 'oxygraphic' plot of oxygen concentration over time. Highest signal stability minimizes the required amounts of biological sample, and provides the basis for resolution in the extreme low-oxygen range. Peltier temperature control provides a thermal stability at Β±0.002 Β°C in the range of 4 Β°C to 47 Β°C at typical constant room temperature. Electronically controlled PVDF or PEEK stirrers are integrated in the two-chamber design of the O2k, and a barometric pressure transducer enables automatic oxygen calibrations implemented in the DatLab software. The O2k is a sole source apparatus with no other instruments meeting its [[MiPNet06.05 Test Experiments on O2k-Specifications | specifications]]. |info=[[Gnaiger_2008_POS]] }} :::* The '''O2k-Core''' does not include, but fully supports and is required for the add-on O2k-Modules: [[Titration-Injection microPump|TIP2k]], [[O2k-Fluo LED2-Module]], [[O2k-TPP+ ISE-Module]], [[O2k-pH ISE-Module]], [[O2k-NO Amp-Module]]. :::* A PC is required (not included), connecting DatLab to the O2k via a USB port. For PC requirements, see [[DatLab#PC requirements| here]]. [[File:Questions.jpg|left|40px]] <br /> <div class="toccolours mw-collapsible mw-collapsed"> ::: <span style="font-size:105%; color:##424242">'''Β» Keywords'''</span> <div class="mw-collapsible-content"> ::: '''Specific''' ::::Β» [[DatLab]] ::::Β» [[DatLab#PC requirements|DatLab PC requirements]] ::::Β» [[ISS-Integrated Suction System]] ::::Β» [[Oroboros O2k]] ::::Β» [[O2k-Assembly Kit]] ::::Β» [[O2k-Main Unit]] ::::Β» [[O2k-Titration Set]] ::::Β» [[OroboPOS]] ::::Β» [[OroboPOS-Service Kit]] ::::Β» [[MiPNet06.05 Specifications | Oxygraph specifications]] ::: '''General''' ::::Β» [[O2k-Fluo LED2-Module]] ::::Β» [[High-resolution respirometry]] ::::Β» [[O2k-NO Amp-Module]] ::::Β» [[O2k-pH ISE-Module]] ::::Β» [[O2k-TPP+ ISE-Module]] ::::Β» [[Titration-Injection microPump|TIP2k]] </div> </div> <br /> == O2k-Core manual and selected protocols == ::::Β» <big>'''[[Media:MiPNet19.18 O2k-Core Manual.pdf|Contents: O2k-Core Manual DatLab 6.pdf]]'''</big> {{#ask:[[Category:Publications]] [[Additional label::O2k-Core]] | mainlabel=Chapter |?Has info=View |?Has title=Section |?Was published in year=Last update |format=broadtable |limit=500 |sort= |order=ascending |offset=0 }} [[File:Oxygraph-2k-Concept.jpg|400px|right]]
Save page Show preview Show changes Cancel