Difference between revisions of "NextGen-O2k Documentation"
From Bioblast
Tindle Lisa (talk | contribs) |
Tindle Lisa (talk | contribs) |
||
Line 32: | Line 32: | ||
* '''Q-service''' | * '''Q-service''' | ||
[https://www.youtube.com/watch?v=LlIKDFDDeyQ&feature=youtu.be Assembly of the reference electrode] | [https://www.youtube.com/watch?v=LlIKDFDDeyQ&feature=youtu.be Assembly of the reference electrode]<br> | ||
[https://www.youtube.com/watch?v=EOra9oYgbmU&feature=youtu.be NG Polishing glassy carbon and platinum electrodes] | [https://www.youtube.com/watch?v=EOra9oYgbmU&feature=youtu.be NG Polishing glassy carbon and platinum electrodes]<br> | ||
[https://www.youtube.com/watch?v=vFmHBevN8f4&feature=youtu.be NG O2k-Chamber volume calibration with Q-Sensor] | [https://www.youtube.com/watch?v=vFmHBevN8f4&feature=youtu.be NG O2k-Chamber volume calibration with Q-Sensor]<br> | ||
--------- | --------- | ||
Line 44: | Line 44: | ||
* ''' Cleaning Q-Sensors''' | * ''' Cleaning Q-Sensors''' | ||
[https://www.youtube.com/watch?v=D9PaFcB_yKk&feature=youtu.be NG Cleaning after cyclic voltammetry] | [https://www.youtube.com/watch?v=D9PaFcB_yKk&feature=youtu.be NG Cleaning after cyclic voltammetry]<br> | ||
[https://www.youtube.com/watch?v=-VXGTVc3ywA&feature=youtu.be NG Cleaning after Q-experiments] | [https://www.youtube.com/watch?v=-VXGTVc3ywA&feature=youtu.be NG Cleaning after Q-experiments] | ||
Line 55: | Line 54: | ||
<div class="mw-collapsible-content"> | <div class="mw-collapsible-content"> | ||
[https://www.youtube.com/watch?v=nlVLXcbBRqs Smart Fluo-Sensor assembly]<br> | |||
[https://www.youtube.com/watch?v=eUukvgAi1yY Exchanging a filter set of the smart-fluo sensor]<br | |||
>[https://www.youtube.com/watch?v=_Fv0VSA_c14 H<sub>2</sub>O<sub>2</sub> flux analysis with DatLab 7.4] | |||
[https://www.youtube.com/watch?v=_Fv0VSA_c14 H<sub>2</sub>O<sub>2</sub> flux analysis with DatLab 7.4] | |||
</div> | </div> | ||
</div> | </div> | ||
Line 69: | Line 65: | ||
<div class="mw-collapsible-content"> | <div class="mw-collapsible-content"> | ||
[https://www.youtube.com/watch?v=EjQGUr5M8v0&feature=youtu.be Shredder tissue homogenate] | [https://www.youtube.com/watch?v=EjQGUr5M8v0&feature=youtu.be Shredder tissue homogenate]<br> | ||
[https://www.youtube.com/watch?v=iN38rOkiBUQ&feature=youtu.be Fiber permeabilization]<br> | |||
[https://www.youtube.com/watch?v=iN38rOkiBUQ&feature=youtu.be Fiber permeabilization] | |||
[https://www.youtube.com/watch?v=GX_SvnVGXgg Addition of biological sample to the respirometer chamber] | [https://www.youtube.com/watch?v=GX_SvnVGXgg Addition of biological sample to the respirometer chamber] | ||
Revision as of 09:13, 26 May 2021
Template:MitoFit highlights page name
The revolutionary all-in-one instrument to conquer mitochondrial disease.
WP3: Documentation
Abstract
- In Workpackage 3 a complete set of SOPs, user manuals, tutorial videos and webinars for the NextGen-O2k will be generated. Training courses for customers as well as for staff will be developed and offered.
Achievements
- Project Year 1: In year one of the project, we aimed to improve the reproducibility of experimental results and support customers with new developments. Therefore, we created an SOP for the new Q-Module, 6 new manuals and O2k-Videosupport clips for the Q-Module, DatLab7.4, mitochondrial preparations, and TPP+ and ISE electrodes.
- Project Year 2: Year 2 proved to be a continuation of the development of SOPs and video clips. A PB-Module manual was released for the algae KOLs and new video clips ranged from basic set-up and quality control to more advanced techniques like the DIC saturation curve using the PB Module.
Progress and next steps
- See » Track record
NextGen-O2k Videosupport clips
Q-Module (NextGen-O2k - DatLab 7)
FluoRespirometry
O2k-Mitochondrial preparations