Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "MiPNet24.14 O2k-sV-Module manual"

From Bioblast
 
(8 intermediate revisions by 4 users not shown)
Line 5: Line 5:
|info=[[Image:PDF.jpg|100px|link=https://wiki.oroboros.at/images/0/0c/MiPNet24.14_O2k-sV-Module.pdf|Bioblast pdf]] »[https://wiki.oroboros.at/index.php/File:MiPNet24.14_O2k-sV-Module.pdf Versions]
|info=[[Image:PDF.jpg|100px|link=https://wiki.oroboros.at/images/0/0c/MiPNet24.14_O2k-sV-Module.pdf|Bioblast pdf]] »[https://wiki.oroboros.at/index.php/File:MiPNet24.14_O2k-sV-Module.pdf Versions]
|authors=Oroboros
|authors=Oroboros
|year=2019-10-23
|year=2020-03-17
|journal=Mitochondr Physiol Network
|journal=Mitochondr Physiol Network
|abstract=''' Passrugger M, Gallée L, Krumschnabel G, Tindle-Solomon L, Gnaiger E, Doerrier C (2019) O2k-sV-Module manual. Mitochondr Physiol Network 24.14(01):1-8.'''
|abstract= Passrugger M, Garcia-Souza LF, Tindle-Solomon L, Gnaiger E, Doerrier C (2020) O2k-sV-Module manual. Mitochondr Physiol Network 24.14(03):1-8.
 
{{MiPNet pdf page linking to MitoPedia}}
'''O2k-Manual''': The O2k-sV-Module is a modular extension of the O2k specifically designed to perform high-resolution respirometry with reduced amount of biological sample and chemicals, leading to an overall decrease of running costs and expanding the application scope of samples with limited availability. The O2k-sV-Module exchanges the standard 2 mL O2k-Chamber for a smaller operation volume of 0.5 mL.
The O2k-sV-Module is compatible with all O2k-Series, however it cannot be used for simultaneous measurement of multiple parameters in the O2k-FluoRespirometer or in combination with the O2k-MultiSensor Modules. The use of O2k-sV-Module is recommended at normoxic range, in a narrow experimental range of oxygen concentration near air saturation to reduce technical problems of oxygen diffusion and instrumental O<sub>2</sub> background.
 
:» Product:[[O2k-sV-Module]], [[Oroboros O2k-Catalogue]]
:» Product:[[O2k-sV-Module]], [[Oroboros O2k-Catalogue]]
|mipnetlab=AT_Innsbruck_Oroboros
|mipnetlab=AT_Innsbruck_Oroboros
}}
}}
{{MitoPedia without banner
|abbr=O2k-sV-Module
|description=The '''O2k-sV-Module''' consists of two 0.5 mL glass chambers and accessories for insertion into the O2k, for respiratory measurements with small amounts of sample, providing flexibility in addition to the standard 2 mL chamber.
|info=
}}
__TOC__
{{Technical support integrated}}


{{Labeling
{{Labeling
|area=Instruments;methods
|area=Instruments;methods
|instruments=Oxygraph-2k, O2k-Fluorometer, O2k-Manual
|instruments=Oxygraph-2k, O2k-Manual
|additional=DatLab,
|additional=DatLab, DL7, O2k-Module
}}
}}

Latest revision as of 11:51, 27 July 2023

                



MiPNet24.14 O2k-sV-Module manual


Publications in the MiPMap
O2k-Manual
O2k-sV-Module manual.

» Bioblast pdf »Versions

Oroboros (2020-03-17) Mitochondr Physiol Network

Abstract: Passrugger M, Garcia-Souza LF, Tindle-Solomon L, Gnaiger E, Doerrier C (2020) O2k-sV-Module manual. Mitochondr Physiol Network 24.14(03):1-8.

O2k-technical support and open innovation
Open the pdf document above.
» Current O2k-series: NextGen-O2k Series XB and O2k Series J
» Current software versions DatLab 8.0: MitoPedia: DatLab
» Product:O2k-sV-Module, Oroboros O2k-Catalogue


O2k-Network Lab: AT_Innsbruck_Oroboros


Labels: MiParea: Instruments;methods 





HRR: Oxygraph-2k, O2k-Manual 

DatLab, DL7, O2k-Module