<ins>''TIP2k - 2-Channel Titration-Injection microPump:''</ins> The TIP2k provides unique advantages for applications which require highest accuracy of titration volumes and automatic control of complex titration-injection protocols. The TIP2k was specially developed for the Oxygraph-2k. The main modes of operation are automatic multi-step injections, continuous injections for steady-state respirometry, (both operated form the direct control mode), and feedback controlled operation. | |||
<ins>''Direct Control Mode:'' </ins>Operation mode for delivering a defined volume in a short pulse. A number of cycles, N, can be defined, and the duration of the interval from injection to injection determined, repeating the process N times. Several such steps can be programmed to run in sequence to give an entire TIP program. | |||
<ins>''Feedback Control Mode:''</ins> Operation mode to reach and maintain a certain parameter (e.g. oxygen concentration) by automatic TIP injections. | |||
:>> O2k-Manual: [http://www.oroboros.at/?o2k-manual Overall contents] | :>> O2k-Manual: [http://www.oroboros.at/?o2k-manual Overall contents] | ||
:>> Product: [http://www.oroboros.at/?oxygraph OROBOROS Oxygraph-2k], [[O2k-Catalogue_OROBOROS| O2k-Catalogue]] | :>> Product: [http://www.oroboros.at/?oxygraph OROBOROS Oxygraph-2k], [[O2k-Catalogue_OROBOROS| O2k-Catalogue]] |
Revision as of 10:23, 17 October 2013
Fasching M, Lukas Gradl L, Gradl P, Erich Gnaiger E (2007) Titration-Injection microPump TIP2k. User manual. Mitochondr Physiol Network 12.10. |
» Open Access-MiPNet12.10.pdf; Versions
OROBOROS (2007) Mitochondr Physiol Network
Abstract: O2k-Manual Chapter F
TIP2k - 2-Channel Titration-Injection microPump: The TIP2k provides unique advantages for applications which require highest accuracy of titration volumes and automatic control of complex titration-injection protocols. The TIP2k was specially developed for the Oxygraph-2k. The main modes of operation are automatic multi-step injections, continuous injections for steady-state respirometry, (both operated form the direct control mode), and feedback controlled operation.
Direct Control Mode: Operation mode for delivering a defined volume in a short pulse. A number of cycles, N, can be defined, and the duration of the interval from injection to injection determined, repeating the process N times. Several such steps can be programmed to run in sequence to give an entire TIP program.
Feedback Control Mode: Operation mode to reach and maintain a certain parameter (e.g. oxygen concentration) by automatic TIP injections.
- >> O2k-Manual: Overall contents
- >> Product: OROBOROS Oxygraph-2k, O2k-Catalogue
• Keywords: HRR, TIP2k
• O2k-Network Lab: AT_Innsbruck_OROBOROS
Labels: MiParea: Instruments;methods
HRR: Oxygraph-2k, TIP2k, O2k-Manual, Protocol"Protocol" is not in the list (Oxygraph-2k, TIP2k, O2k-Fluorometer, pH, NO, TPP, Ca, O2k-Spectrophotometer, O2k-Manual, O2k-Protocol, ...) of allowed values for the "Instrument and method" property.
O2k-SOP, DatLab
Furter information
- >> MiPNet12.10
- >> MiPNet09.10 is integrated in MiPNet12.10 TIP2k-Manual
- Version 5: 2011-12-11
- Version 1: 2007