|description=A '''Cover-Slip''' should be placed on top of the O2k-Stopper to minimize contamination and evaporation of liquid extruding from the capillary of the stopper.Β The Cover-Slips do not exert any direct effect on oxygen backdiffusion into the [[O2k-Chamber]]. Use the the '''Cover-Slip\black''' to avoid light penetration and disturbance of fluorescence signals and generally for optical measurements in the Oxygraph-2k. | |description=A '''Cover-Slip''' should be placed on top of the O2k-Stopper to minimize contamination and evaporation of liquid extruding from the capillary of the stopper.Β The Cover-Slips do not exert any direct effect on oxygen backdiffusion into the [[O2k-Chamber]]. Use the the '''Cover-Slip\black''' to avoid light penetration and disturbance of fluorescence signals and generally for optical measurements in the Oxygraph-2k. | ||
[[O2k- | Β | ||
Two units of this item are standard components of the [[O2k-Assembly Kit]] ([[O2k-Core]]). | |||
|product id=24411-01 | |product id=24411-01 | ||
|product type=O2k, O2k-Assembly Kit, Stopper | |product type=O2k, O2k-Assembly Kit, Stopper | ||
|product image=[[Image:Cover-Slip_black.JPG|180px|right]] | |product image=[[Image:Cover-Slip_black.JPG|180px|right]] | ||
}} | }} | ||
* Cover-Slips cannot be placed on top of the stoppers in O2k-MultiSensor applications with additional sensors inserted through the stopper, or while [[TIP2k]] needles are inserted into the O2k-Chamber. | * Cover-Slips cannot be placed on top of the stoppers in O2k-MultiSensor applications with additional sensors inserted through the stopper, or while [[TIP2k]] needles are inserted into the O2k-Chamber. | ||
* The black cover-slips replaced the previous perspex [[Cover-Slip]]s (Product ID 24410-01). They are functionally identical, but the black cover slips | * The black cover-slips replaced the previous perspex [[Cover-Slip]]s (Product ID 24410-01). They are functionally identical, but the black cover slips take into account the optical properties of the [[O2k-Fluorometer]] and prevent light from penetrating through the capillaries of the stoppers when using optical sensors. |
Revision as of 15:16, 19 February 2015
Cover-Slip\black
Description | A Cover-Slip should be placed on top of the O2k-Stopper to minimize contamination and evaporation of liquid extruding from the capillary of the stopper. The Cover-Slips do not exert any direct effect on oxygen backdiffusion into the O2k-Chamber. Use the the Cover-Slip\black to avoid light penetration and disturbance of fluorescence signals and generally for optical measurements in the Oxygraph-2k.
|
---|---|
Product ID | 24411-01 |
Type | O2k, O2k-Assembly Kit, Stopper |
Link | |
Image |
- Cover-Slips cannot be placed on top of the stoppers in O2k-MultiSensor applications with additional sensors inserted through the stopper, or while TIP2k needles are inserted into the O2k-Chamber.
- The black cover-slips replaced the previous perspex Cover-Slips (Product ID 24410-01). They are functionally identical, but the black cover slips take into account the optical properties of the O2k-Fluorometer and prevent light from penetrating through the capillaries of the stoppers when using optical sensors.