Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Search results

From Bioblast
Results 1 – 19 of 19
Advanced search

Search in namespaces:

  
  
  
  
  
  
  
  
  
  
  
  
  

Page title matches

  • ...iption=In '''Copy marks''', [[Marks - DatLab |Marks in DatLab]] are copied from a seleted [[Plot - DatLab |Plot]] to the active plot. {{Keywords: Marks in DatLab}}
    392 bytes (54 words) - 11:29, 25 March 2022
  • [[File:DL8_copy_marks_window.png|thumb|none|400px|Copy marks window]]
    324 bytes (38 words) - 08:49, 5 April 2022

Page text matches

  • ...iption=In '''Copy marks''', [[Marks - DatLab |Marks in DatLab]] are copied from a seleted [[Plot - DatLab |Plot]] to the active plot. {{Keywords: Marks in DatLab}}
    392 bytes (54 words) - 11:29, 25 March 2022
  • ...he titration volume preceding each mark. (6) Go to 'Mark statistics' [F2], copy to clipboard, and paste into the sample tab in the DatLab-Analysis template
    2 KB (264 words) - 05:05, 11 January 2019
  • [[File:DL8_copy_marks_window.png|thumb|none|400px|Copy marks window]]
    324 bytes (38 words) - 08:49, 5 April 2022
  • ...l marks", with 3 possibilities each), then click on [Copy to clipboard] to copy selected values and paste them to a '''DatLab-Analysis template''' for nume ::::# Create a copy for your data analysis.
    4 KB (574 words) - 11:36, 25 March 2022
  • ...' one [[Plot - DatLab |Plot]] is selected as a source for [[Marks - DatLab|Marks]] over sections of time. Values (e.g. medians) are displayed for these time :::# Set the [[MitoPedia:_DatLab#Marks|Marks in DatLab]] on a selected (active) [[Plot in DatLab |Plot]].
    6 KB (916 words) - 20:54, 11 June 2023
  • ::::» [[Copy to clipboard]] [[File:Marks-menu.png|right|150px]]
    5 KB (686 words) - 11:27, 10 April 2024
  • ...or plot and press F5 to open the calibration window, or select the channel from the Calibration menu, or press the Amp (or pX) buttons in the O2k-status li ...ad concentrations from a previous calibration (same mark names) using Copy from file (2b). The values associated with the mark will be updated if the conce
    2 KB (337 words) - 11:22, 7 February 2022
  • ...sensor test. DatLab analysis of a two-point O<sub>2</sub> calibration, set marks on O<sub>2</sub> concentration, enter O<sub>2</sub> solubility factor; use ...s of a file obtained in an instrumental O<sub>2</sub> background test; set marks on O2 slope (neg.); calculate instrumental O<sub>2</sub> background paramet
    6 KB (767 words) - 16:54, 29 August 2022
  • ...DL-Protocol/Set O2 limit. A DL-Protocol defines the sequence of Events and Marks. By clicking on "Show" a demo DL-Protocol will be opened. Templates for sto ..., brief explanatory texts and templates for data evaluation can be browsed from inside DatLab 7.4.
    10 KB (1,339 words) - 09:33, 6 May 2021
  • .../span> in menu File. The calibration file is saved, and DatLab disconnects from the O2k. ...section, and clicking on <span style="background:lightgrey">Calibrate and copy to clipboard</span> in the O2 calibration window (in menu 'Calibration' > '
    26 KB (3,995 words) - 10:15, 7 October 2021
  • :::::: <big>''Answered Questions from the »[[Oroboros Ecosystem Agenda 2020 Archive]]« |''' Did you know the reverse electron flow from Complex II to Complex I can be investigated in mitochondrial preparations b
    27 KB (4,026 words) - 11:53, 29 March 2021
  • ::: '''AmR: Amplex® UltraRed''' from Life Technologies (former Invitrogen): A36006; 5* 1 mg commercial vials, st ...ided into 20 µL aliquots and stored in the dark in a desiccator, protected from moisture at –20°C for future use. When stored properly, the 10 mM storag
    35 KB (5,265 words) - 15:10, 25 April 2024
  • ...standardized instrumental O<sub>2</sub> background test. The oxygen regime from air saturation towards zero oxygen is applied generally in experiments with ...ection at air saturation subtracts the consumption of oxygen by the sensor from the negative slope when diffusion into and out of the chamber is zero at ai
    19 KB (2,868 words) - 10:11, 22 April 2022
  • :from the O2k-Network »[[US CA San Francisco Nussbaum RL]]« and »[[DE Frankfur Neither. There is simultaneous electron transfer from FAO into the Q-junction through the electron transferring flavoprotein dehy
    25 KB (3,611 words) - 08:22, 22 April 2024
  • ...pTPP, pCa, etc., hence the general term “pX” is used to denote the signal from such an ISE. ...e stored in this condition. Carefully unwind the tape and remove the probe from the protective glass tube.
    37 KB (5,713 words) - 12:13, 28 February 2023
  • :from the O2k-Network »[[NZ Auckland Hickey AJ]]« :from the O2k-Network »[[AU Sydney Philp A]]«
    126 KB (17,785 words) - 08:55, 13 August 2021
  • Find out in the review from [[FAT4BRAIN]] partners. <br> :from the O2k-Network »[[ES Barcelona Garcia-Roves PM]]«, »[[ES Barcelona Clar
    87 KB (11,941 words) - 15:14, 16 November 2023