Stopper\black PEEK\conical Shaft\central Port: Difference between revisions
From Bioblast
No edit summary |
No edit summary |
||
Line 2: | Line 2: | ||
|description='''Stopper\black PEEK\conical Shaft\central Port''': with conical shaft and one central capillary (with PTFE, graphite, carbon fiber), [[Volume-Calibration Ring]] (A or B) for volume adjustment 1.5 to 3.2 ml; 2 mounted O-rings ([[O-ring\Viton\12x1 mm]]). The black PEEK stoppers are required for optical O2k-MultiSensor Modules ([[O2k-Fluorescence LED2-Module]]). | |description='''Stopper\black PEEK\conical Shaft\central Port''': with conical shaft and one central capillary (with PTFE, graphite, carbon fiber), [[Volume-Calibration Ring]] (A or B) for volume adjustment 1.5 to 3.2 ml; 2 mounted O-rings ([[O-ring\Viton\12x1 mm]]). The black PEEK stoppers are required for optical O2k-MultiSensor Modules ([[O2k-Fluorescence LED2-Module]]). | ||
|product id=24000-01 | |product id=24000-01 | ||
|product type=O2k, O2k-Assembly Kit, MultiSensor, O2k-Fluorescence LED2-Module, Stopper | |product type=O2k, O2k-Assembly Kit, MultiSensor, O2k-Fluorescence LED2-Module, Stopper, O2k-Manual | ||
|info=Previous Product ID 31220-34, [ | |info=Previous Product ID 31220-34, [[O2k-Fluorescence LED2-Module]] | ||
|product image=[[File:Stopper black PEEK conical Shaft central Port.JPG|right|180px|link=]] | |product image=[[File:Stopper black PEEK conical Shaft central Port.JPG|right|180px|link=]] | ||
}} | }} | ||
* [[O2k-Core]]: 2 stoppers in [[O2k-Assembly Kit]]; alternatively, 2 white stoppers [[Stopper\white PVDF\conical Shaft\central Port]]. The stoppers are placed in the [[O2k-Service Box]] for shipment. | * [[O2k-Core]]: 2 stoppers in [[O2k-Assembly Kit]]; alternatively, 2 white stoppers [[Stopper\white PVDF\conical Shaft\central Port]]. The stoppers are placed in the [[O2k-Service Box]] for shipment. | ||
== O2k-Manual == | |||
=== Stoppers === | |||
Use only [[Stopper\black PEEK\conical Shaft\central Port|black PEEK stoppers]] in conjunction with optical measurements ([[O2k-Fluorescence LED2-Module]]). If necessary, replace the previous white PVDF stoppers. The black stoppers can be used for all HRR applications in general. See [[MiPNet12.06]] for calibration of the O2k-chamber volume, which is identical for PEEK and PVDF stoppers. |
Revision as of 20:39, 11 March 2012
Stopper\black PEEK\conical Shaft\central Port
Description | Stopper\black PEEK\conical Shaft\central Port: with conical shaft and one central capillary (with PTFE, graphite, carbon fiber), Volume-Calibration Ring (A or B) for volume adjustment 1.5 to 3.2 ml; 2 mounted O-rings (O-ring\Viton\12x1 mm). The black PEEK stoppers are required for optical O2k-MultiSensor Modules (O2k-Fluorescence LED2-Module). |
---|---|
Product ID | 24000-01 |
Type | O2k, O2k-Assembly Kit, MultiSensor, O2k-Fluorescence LED2-Module, Stopper, O2k-Manual"O2k-Manual" is not in the list (O2k, O2k-Module, O2k-Core, O2k-Fluorometer, O2k-Main Unit, O2k-Assembly Kit, OroboPOS, OroboPOS-Service Kit, ISS, TIP2k, ...) of allowed values for the "Product type" property. |
Link | Previous Product ID 31220-34, O2k-Fluorescence LED2-Module |
Image |
- O2k-Core: 2 stoppers in O2k-Assembly Kit; alternatively, 2 white stoppers Stopper\white PVDF\conical Shaft\central Port. The stoppers are placed in the O2k-Service Box for shipment.
O2k-Manual
Stoppers
Use only black PEEK stoppers in conjunction with optical measurements (O2k-Fluorescence LED2-Module). If necessary, replace the previous white PVDF stoppers. The black stoppers can be used for all HRR applications in general. See MiPNet12.06 for calibration of the O2k-chamber volume, which is identical for PEEK and PVDF stoppers.